Current:Home > +Power plant IPP
+Power plant IPP
MANAGEMENT RELAY
2016-11-20 16:38:04
 

TRNSFORMER MANAGEMENT RELAY, TYPE:WDZ-440 EX TRNSFORMER MANAGEMENT RELAY, POWER BOARD,VOLT:+5V +24 V TYPE:EMWEX-300 ; CONTROL BOARD:EMWEX-599;CPU BOARD:EMWEX-400;AI BOARD:EMWEX-757 ,WISCOM SYSTEM,CONTROL VOLTAGE 220 VDC,FOR 11KV TRANSFORMER PROTECTION

TYPE:WDZ-430 EX MOTOR MANAGEMENT RELAY POWER BOARD,VOLT:+5V +24 V TYPE:EMXWE-300 ; I/O:MWEX-605;CPU BOARD:EMWEX-400;AI BOARD:EMWEX-755 ,WISCOM SYSTEM,FOR 11KV MOTOR PROTECTION

RELAY, CONTROL; P/N: WDZ-491EX, WISCOM SYSTEM; CONTACT RATING: 5 A, COIL VOLTAGE: 220 VDC, TYPE:VT MANAGEMENT

 
 
1, the remote signal: the device a total of 14 open into the volume, of which: 12-way for the acquisition of external remote, 2-way signal for the internal switch
2, power consumption: <0.5VA / each phase
3, for less demanding working conditions, operation control is simple, little impact on the production of stand-alone operation of the motor, the choice of ordinary type protector, simple structure of the protector, in the field installation wiring, easy to replace, easy to operate , With a cost-effective features.
4, provides five non-power protection, from a main device body to the non-electrical signals (such as temperature, **, etc.), from the opening into the volume (IN08 ~ IN12) access to the device, as non-battery protection, protection Independent vote back.
5, microcomputer relay protection device program changes should be supervised by the relay protection agency issued a notice of strict implementation of the procedures.
6, when the line occurs when the single-phase ground, will produce zero sequence current, zero sequence current by a dedicated zero sequence transformer input device, when the zero sequence current is greater than the set value of the zero sequence current, the (time can be set) , The device exports.
7, loss of voltage protection: When the system power disappears, the time can be set to protect the action. The system power dissipation criterion combines the no-voltage and no-flow conditions.
8, when any phase current is greater than the speed of protection after the current setting, the time can be set to protect the action.
9, when any phase current is greater than the definite time overcurrent protection settings, the (time can be set), the device exports trip.
10, rated current: 5A (1A rated current must be specified when ordering)
11, each screen displays a maximum of 30 **, display content including ** serial number (01 ~ 30), ** occurrence time (time format mm dd-hh: mm: ss.ms) and the corresponding ** simple text description .
12, 110kV and above the system microcomputer relay protection settings required for the calculation of the power of the main equipment and line parameters, should use the measured parameter values.
13, If the circuit breaker is in the closing position, the "position" indicator will be on, and the "position indicator" will be off. If the circuit breaker is in the opening position, the "position" indicator will be off.
14, custom protection can be achieved standard protection library does not provide special protection, the maximum to meet user requirements.
15, "self-test" indicator (orange) is used to indicate the device self-test signal.
16, when the display is in the main menu state, "▲", "▼" button is used to move the bar cursor up and down, press the "enter" key to enter the submenu or the corresponding screen state, the main menu does not respond to " Button operation.
17, the panel module through the parallel communication from the host module to receive system parameters, protection settings and other data.
18, all microcomputer relay protection device and other digital equipment communication protocol should be unified.
19,10 (6) KV high voltage motor unit protection and control
20, as engineers in the field maintenance, upgrading or replacement of products, you need to disconnect the device and the operating system of all electrical wiring.
 
Related models
GRT-1851 microcomputer line protection and control device
SZT-531 plant with protection and monitoring devices
BKB-302 transformer backup protection
WBH-812A transformer protection device
Application of BW - ML2000 Microcomputer - based Earthed Line Selection Device
WMH-31A / 02 busbar protection device
GZ22010-9 intelligent high-frequency switching power supply
EMA500 microprocessor-based protection and control devices
WMH-500 microcomputer-based bus protection device
WGB-871 microcomputer integrated protection device
DMR300P digital multi-function relay
WBH-92A / 01S transformer differential protection device
HYJC300 Insulation Monitoring Management Unit
REF-500G microprocessor-based protection and control devices
NSA3121A station with variable protection and monitoring devices
DF3322EB subsection protection and monitoring device
DF1925 integrated monitoring module
WT-2021B transformer differential protection device
YZ600-DD Motor Differential Protection and Control Device
PMC-851V voltage measurement and control devices
GLC-1811 Capacitor Protection Device
YKS-511 line protection and control devices
X-B9000XL line protection and control devices
CSR-03B line protection device
EDCS-7460B Standby power automatic input device
PMC-800G generator protection and monitoring device
TK28-ZBX line protection device
DMP311C1 line protection and control devices
BHE-370 microprocessor-based regulator protection device
Z600F transformer differential protection
YXSL-631 digital line protection and control devices
BST-203 integrated protection device
OMT-531 plant with variable protection
ISA-388GL transformer low back-up protection device
LVL201 line monitoring and protection devices
BHE-375 transformer backup protection
WDZ-5212 line optical fiber differential protection and control device
KLD-9332 back-up protection and control devices
WXH-1000 microcomputer integrated grounding protection device
PRS-771 bus monitoring and control devices
DCAP-3000 universal protection and monitoring devices
DP200-T transformer main protection
WXH automatic ** compensation arc suppression coil control device
KLD-9351 capacitor protection and monitoring devices
UNT-EAP intelligent arc light protection device
PRS-778GD2B transformer protection device
PSRC910 microcomputer line protection and control device
SCM-864 motor protection and monitoring devices
WPY-2 microcomputer frequency voltage automatic control device
STD-620C transformer differential protection and control devices
 

Purchase Process:

Mailto:COMKGC@163.COM

We quotation

Your side confirmed

Released PO to us

We signed PO

You side payment

We delivery goods to your side.

 
 
 
 
 
previous posts:Pressure Relief Valve