2017-11-12 17:14:10
 
 

KFW2-1600 ACB SPRING CHARGE MOTOR MECH

MOTOR;TYPE: SPRING CHARGING, APPLICATION: AIR CIRCUIT
BREAKER; EQUIP/TAG MODEL: KFW2-1600,SERIAL NO.070321014
OEM: KFINE

KFW2-1600 ACB SLIDING CONTACT

CONTACT, MOVEABLE; REFERENCE: KFW2-1600
FFT: FOR AIR CIRCUIT BREAKER; OEM: KFINE;
Serial no.070321059
GA Drawing to be provided by the Vendor

KFW2-1600 ACB RACK IN/OUT MECHANISM

MECHANISM;TYPE IN/OUT; REF: REFERENCE: KFW2-1600
FFT: FOR AIR CIRCUIT BREAKER RACK; Serial no.070421059
OEM: KFINE

MICROGAP SWITCH 1NO+1NC

SWITCH;
TYPE: MICROGAP SWITCH (SPRING CHARGE LIMIT SWITCH),
POTENTIAL FREE: 380 V, CONTACT
ARRANGEMENT: 1NO+1NC, CURRENT: 5 A
APPLN: VACUUM CIRCUIT BREAKER 1250A (ZN63A(VS1)-12T

6.6KV SWITCHGEAR TRIP COIL

COIL, ELECTRICAL;
POTENTIAL 6.6 KV; REF: REFERENCE: ZO7F3833
FFT: FOR SWITCHGEAR

KFW2-1600 ACB CLOSE/TRIP COIL

COIL, ELECTRICAL;
TYPE: AIR CIRCUIT BREAKER CLOSE/TRIP; REFERENCE:
KFW2-1600,

KFW2-3200 ACB CLOSE/TRIP COIL

COIL, ELECTRICAL;
TYPE: AIR CIRCUIT BREAKER CLOSE/TRIP; REFERENCE:
SERIES KFW2-3200

UNIT CNTRL;INTELLIGENT TRIP 3P 400A

"UNIT, CONTROL; TYPE INTELLIGENT TRIP 3P 400A, SUPPLY 24 DC V, SPECIFICATION UNIT 4; OEM: KFINE; Serial no.070321059

UNIT CNTRL;INTELLIGENT TRIP 4P 630A

"UNIT, CONTROL; TYPE INTELLIGENT TRIP 4P 630A, SUPPLY 24 DC V, SPECIFICATION UNIT 2; OEM: KFINE; Serial no.070421229

AIR CIRCUIT BREAKER 400A

BREAKER, CIRCUIT, AIR;
MAKING COIL VOLTAGE: 220 VDC, BREAKING COIL
VOLTAGE: 220 VDC, CHARGING MOTOR POTENTIAL: 220 VDC
CURRENT: 400 A, POTENTIAL: 415 V, FREQUENCY: 50 HZ
ELECTRICAL POLE QUANTITY: 4; F:/USED ON: CLOSE
COIL 220VDC; TRIP COIL 220VDC; CHARGING MOTOR
220VDC; ELECTRICAL POLE QUANTITY:3, AUXILIARY CONTACTS:8NO+8NC,
PROTECTION RELEASE SUPPLY: 24V DC, Ics=Icu=Icw=50KA
Ics=Icu=Icw=50KA ; Icw=50KA for 1s)
MAKE - Kfine;KFW2-1600 ACB UNIT 4 INT TRIP UNIT Serial no.070421059
Test report required.

 
 

KFW2-1600 ACB SPRING CHARGE MOTOR MECH

MOTOR;TYPE: SPRING CHARGING, APPLICATION: AIR CIRCUIT,BREAKER; EQUIP/TAG MODEL: KFW2-1600,

KFW2-1600 ACB UNIT 4 INT TRIP UNIT

BREAKER, CIRCUIT, AIR;REFERENCE: KFW2-1600; FFT: WITH TRIP UNIT 4 INT

VACUUM CIRCUIT BREAKER,1250 A

BREAKER, CIRCUIT, VACUUM;BREAKER, CIRCUIT, VACUUM; CURRENT: 1.25 KA;"Type                    : ZN63A(VS1)-12T;Rated Current       : 1250A;Rated Voltage       : 12KV;Rated short circuit;breaking current   : 40KA;Weight               : 150Kg;GA Drawing required for technical acceptance

RELAY PCK TOP9140G-20C

RELAY, CONTROL;RELAY, CONTROL; REFERENCE: PCK TOP9140G-20C,

KFW2-1600 ACB SLIDING CONTACT

SLIDING CONTACT (MALE & FEMALE CONNECTOR):For Breaker Type: KFW2-1600;GA Drawing required for technical acceptance

KFW2-1600 ACB RACK IN/OUT MECHANISM

MECHANISM (RACK IN/OUT);For Breaker Type: KFW2-1600

HSG

HOUSING;TYPE KFW2-1600/4P BREAKER HOUSING,FOR BREAKERS;RATED UPTO 1250A, APPLICATION BREAKERS 4P 400A,630A;800A,1250A, SPECIAL FEATURES BREAKER HOUSING SHALL;HAVE ITS ASSOCIATED MECHANISMS, SPECIFICATION MAKE;JIANGSU KFINE ELECTRIC CO. LTD.,BREAKER HOUSING;SHALL BE SUITABLE FOR BREAKERS UPTO 4P 1250A.; OEM;P/N: kfw2-1600/4p ,OEM: JIANGSU SFERE

HSG;TYP BREAKER HOUSING KFW2-1600/3P

HOUSING;TYPE BREAKER  HOUSING KFW2-1600/3P, APPLICATION FOR;3P 400A AIR CIRCUIT BREAKER, SPECIAL FEATURES;HOUSING EQUIPPED WITH NECESSARY ACCESSORIES,SPECIFICATION MAKE JIANGSU KFINE ELECTRIC CO. LTD.SUITABLE FOR 3P 400A AIR CIRCUIT BREAKER,OEM; OEM; P/N: KFW2-1600/3P,OEM: JIANGSU SFERE

BREAKER ACB 3200 AMPS

Masterpact,Ui-1000v,Uimp 12 kv,Ue 220/440v a.c,480/690v a.c,Icu-65KA,Ics=100% iCu,Icw=65 ka/1s,IEC 60947-2 50/60 hz,Ue=690volts,Ie=3200 amps

UNIT CNTRL;INTELLIGENT TRIP 4P 1600A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,4P, 1600A, SUPPLY 24V DC, TYPE: UNIT 4,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 1250A

INTELLIGENT TRIP UNIT: SUITABLE FOR BREAKER KFW2-1600,4P 1250A, SUPPLY 24V DC, UNIT 4,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 1000A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,4P 1000A, SUPPLY 24V DC, UNIT 4,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 800A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,4P 800A, SUPPLY 24V DC, UNIT 4,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 630A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,4P 630A, SUPPLY 24V DC, UNIT 4,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 400A

INTELLIGENT TRIP UNIT: SUITABLE FOR BREAKER KFW2-1600,4P 400A, SUPPLY 24V DC, UNIT 4,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 3P 400A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,3P 400A, SUPPLY 24V DC, UNIT 4,OEM: KFINE"

UNIT CNTRL INTELLIGENT TRIP 4P 1250A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,4P 1250A, SUPPLY 24V DC, UNIT 2,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 1000A

INTELLIGENT TRIP UNIT: SUITABLE FOR BREAKER KFW2-1600,4P 1000A, SUPPLY 24V DC, UNIT 2,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 800A

INTELLIGENT TRIP UNIT:  SUITABLE FOR BREAKER KFW2-1600,4P 800A, SUPPLY 24V DC, UNIT 2,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 630A

INTELLIGENT TRIP UNIT: SUITABLE FOR BREAKER KFW2-1600,4P 630A, SUPPLY 24V DC, UNIT 2,OEM: KFINE"

UNIT CNTRL;INTELLIGENT TRIP 4P 400A

INTELLIGENT TRIP UNIT: SUITABLE FOR BREAKER KFW2-1600,4P 400A, SUPPLY 24V DC, UNIT 2,OEM: KFINE"

KFW2-3200 ACB RACK IN/OUT MECHANISM

RACK;FFT: FOR AIR CIRCUIT BREAKER, MODEL KFW2-3200,IN/OUT MECHANISM

AIR CIRCUIT BREAKER 400A

BREAKER, CIRCUIT, AIR;MAKING COIL VOLTAGE: 220 VDC, BREAKING COIL;VOLTAGE: 220 VDC, CHARGING MOTOR POTENTIAL: 220 VDC;CURRENT: 400 A, POTENTIAL: 415 V, FREQUENCY: 50 HZ;ELECTRICAL POLE QUANTITY:3, AUXILIARY CONTACTS:8NO+8NC,PROTECTION RELEASE SUPPLY: 24V DC, Ics=Icu=Icw=50KA;Ics=Icu=Icw=50KA ; Icw=50KA for 1s)MAKE - Kfine,Test report required.

SMPS, 230VAC-220VDC/28VDC

POWER SUPPLY;DC-DC CONVERTER, TYPE:KFW2, INPUT VOLTAGE: (110-220VDC),OUTPUT VOLTAGE: 28 VDC, OUTPUT CURRENT: 0.4 ADC

 
 

AVR DISCONNECTING LINK 2500A

FUSE LINK, ELECTRICAL;
TYPE: AUTOMATIC VOLTAGE REGULATOR DISCONNECTING,
CURRENT RATING: 2500 A; MODEL: HD13B-2500A/20/1000V

AVR DISCONNECTING LINK 2000A

FUSE LINK, ELECTRICAL;
TYPE DISCONNECTING, CURRENT RATING 2000 A; P/N:
HD13B-2000A/20/1000V;
FFT: FOR AUTOMATIC VOLTAGE REGULATOR

AVR CPU CARD MBD202

CARD, COMPUTER;
MODEL: MBD202; F:/USED ON: AUTOMATIV VOLTAGE
REGULATOR; CONTROL PROCESSING UNIT

AVR DIGITAL SIGNAL CARD MBD203

REGULATOR, VOLTAGE;
REF: EQUIP/TAG MODEL: MBD203
FFT: FOR AVR DIGITAL SIGNAL CARD

AVR PULSE AMPLIFY CARD MBD204

REGULATOR, VOLTAGE;
REF: EQUIP/TAG MODEL: MBD204
FFT: FOR AVR PULSE AMPLIFY CARD

AVR SYSTEMPOWER CARD MBD205

REGULATOR, VOLTAGE;
POTENTIAL 240VAC; 220VDC; REF: EQUIP/TAG MODEL:
MBD205;FFT: FOR AVR SYSTEM POWER CARD

AVR PULSE POWER CARD MBD206

REGULATOR, VOLTAGE;
POTENTIAL 240VAC; 220VDC; REF: EQUIP/TAG MODEL:
MBD206;FFT: FOR AVR PULSE POWER CARD

AVR POWER SUPPLY CARD MBD207

CARD, ELECTRONIC;
TYPE POWER SUPPLY, POTENTIAL 240VAC;220VDC; P/N:
MBD207; FFT: FOR AUTOMATIC VOLTAGE REGULATOR

AVR BUS BOARD CARD MBD211

CARD, ELECTRONIC;
REF: MODEL: MBD211
FFT: FOR AUTOMATIC VOLTAGE REGULATOR BUS

 

RACKING MECHANISM OF LT BREAKER
TYPE KFW2 630 AMP TO 1600 AMP
 BREAKER MAKE- JIANGSU DAQO KFINE ELECTRIC CO. LTDRefer Attached pic & Document

RACKING MECHANISM OF LT BREAKER
TYPE  KFW2-2000 AMP TO 6300 AMP,
BREAKER MAKE- JIANGSU DAQO KFINE ELECTRIC CO. LTD,Refer Attached pic & Document

FIXED MAIN CONTACT OF AIR CIRCUIT BREAKER,
BREAKER DETAILS -- K FINE ELECTRIC,
TYPE- KFW2-1600 F-50 Hz,
Ue- AC 415 V, Icu- 65 KA, ITU RATING -630 A,
UNIVERSAL AIR CKT BREAKER,Refer Attached pic

Intelligent Trip Unit,
Breaker type: KFW2 ,1600/400-3pole,Refer Attached pic & Document

Intelligent Trip Unit,
Breaker type: KFW2 ,3200/2000-4Pole,Refer Attached pic & Document

Inteligent Trip Unit,
Breaker type: KFW2 , 1600/630-3Pole,Refer Attached pic & Document

SPRING CHARGING MOTOR OF LT AIR CIRCUIT BREAKER
VOLTAGE -220V DC,
BREAKER DETAILS:-  UNIVERSAL AIR CIRCUIT BREAKER,
TYPE- KFW2-1600, In- 630A,Refer Attached pic & Document

LIMIT SWITCH FOR SPRING CHARGING MOTOR
BREAKER DETAILS:-  UNIVERSAL AIR CIRCUIT BREAKER
TYPE- KFW2-1600, In- 630A,Refer Attached pic

Trip Trigger unit of ITU of 1600 A
, Air Circuit breaker, Type- K Fine,Refer Attached pic

Trip Trigger unit of ITU of 3200 A,
Air Circuit breaker, Type- K Fine,Refer Attached pic

Trip Trigger unit of ITU of 4000 A,
Air Circuit breaker, Type- K Fine,Refer Attached pic

 
Air Circuit breaker Shutter assembly complete,
Breaker details:- type- KFW2-3200 A, JIANGSU DAQO KFINE ELECTRIC CO. LTD.Refer Attached pic & Document

 

WWW.COKGC.COM

Enquiry Mailto:

COMKGC@163.COM

→ Quotation

→You Released PO

→We signed

→Payment

→We delivery

Return to home page↑︿︿︿

 
 
 